Dascom 7010 Programmers Manual ZPL Manual de usuario Pagina 13

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 76
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 12
13
^FH
Field Hexadecimal Indicator
Description:
The ^FH command allows you to enter the hexadecimal value for any character directly into the ^FD
statement. The ^FH command must precede each ^FD command in which it will be used.
Within the ^FD statement, the HEX indicator must precede each hexadecimal value. The default
hexadecimal indicator is _(underscore).There must be a minimum of two characters designated to
follow the underscore. The a parameter can be added when a different hexadecimal indicator is
needed.
This command can be used with any of the commands that have field data(i.e. ^FD, ^SN(Serialized
Data)).
Valid hexadecimal characters are;
0123456789ABCDEFabcdef
Format: ^FHa
Parameters:
a = hexadecimal indicator
Accepted Values: any character except current format and control prefix(^and ~ by
default).
Default Value:_(underscore)
Example:
^FO100,100^AD^FH^FDTilde _7e used for HEX^FS
Printer Configuration
^MM
Print Mode
Description:
The ^MM command determines the action the printer takes after a label or group of labels has been
printed. There are four different modes of operation:
1.Tear-Off - After printing, the label is advanced so that the web is over the tear bar. Label,
with backing attached, can then be torn off manually.
Vista de pagina 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 75 76

Comentarios a estos manuales

Sin comentarios