FSL Function Lookup Reference
FUNCTION 1: BUFFER SIZE
This function is used for changing default buffer size.
SYNTAX: %Y1,<n1>%
OPTION DESCRIPTION
1 960 characters
2 1920 characters
3 2560 characters
*4 3440 characters
5 3564 characters
NOTES:
1. This function should not be set during normal operation.
2. Once it has been programmed, the new value should be stored using the "escape X1"
command (see Storing and Restoring Settings) and the printer switched off for 10 seconds and then
on again.
EXAMPLE: %Y1,5%
will set the buffer size to 3564 characters
FUNCTION 2: LPI
This function is used for selecting default LPI.
SYNTAX: %Y2,<n1>%
OPTION DESCRIPTION
0 No LPI sent to printer
6 6 LPI
8 8 LPI
RELATED Y4, Line Spacing
Y5, Form Length
NOTES:
1. At power up the LPI value is loaded from the front panel setup of the printer. Function X1 has
no effect.
2. The system can request different values of LPI. If the system requires default LPI, the value
stored here will be used.
3. If Function 4 is set to 2 (double line spacing), then:
6 = 3 LPI
8 = 4 LPI
4. This function has immediate effect on the printer.
5. LPI from the host may overwrite default.
EXAMPLE: %Y2,8%
20